1. Place the flat cable metal connection toward the connector
2. Carefully place each side notch in the connector’s bracket
3. Carefully close the top hatch of the connector. If the connector is misaligned, it can cause damage, see below.
* Be careful in making the connection, if the connector is misaligned, it can shortcut the display processor, causing permanent damage.
The connector is perpendicular to the display PCB, both notches are in place.
The connector is not perpendicular to the display PCB, only one notch in place. This will short-circuit the board. Beware.
Remove visible corner light spills by breaking associated resistors. Each resistor covers 3 consecutive LED.
The LED strip should run on the outside of the visible glass area.
The LED strip should run on the outside of the visible glass area.
One multi-screen link kit is included in each CrystalFrame integrator kits.
Additional link kits are available on demand, please contact us.
X-Link joint
CRF-QXX-004
T-Link joint
CRF-QXX-005
Metric Screw
ISO 7046-1- M3 x 12 - 4.8
* Network cabling is optional, all control boxes include WiFi capabilities.